Case 3359164

5 Kites Nest Lane, Lightpill, STROUD, GL5 3NR

Stroud District Council — appeal allowed

Outcome
Allowed
Decision date
10 April 2025
Authority
Stroud District Council
Inspector
Edwards J
Procedure
Written Representations
Casework type
Planning Appeal
Type detail
Unknown
Development type
Other minor developments
Appellant
Qiani Ltd
LPA reference
S.24/1964/DISCON
ONS LPA code
E07000082
Jurisdiction
Transferred
Link status
Not Linked
Start date
6 February 2025

Summary AI

The appeal is allowed due to the proposed surface water drainage system being acceptable and not increasing the risk of flooding. The system connects to the combined foul and surface water mains in Kitesnest Lane, which accords with LP policy ES4.

Generated from the decision letter — check against the original before relying on it.

PDF text

Page 1 · Chunk 0 Appeal Decision

5 Kites Nest Lane, Lightpill, STROUD, GL5 3NR — Stroud District Council — Appeal Decision Site visit made on 8 April 2025 by Jonathan Edwards BSc(Hons) DipTP MRTPI an Inspector appointed by the Secretary of State Decision date: 10 April 2025 Appeal Ref: APP/C1625/W/25/3359164 5 Kitesnest Lane, Lightpill, Stroud, Gloucestershire GL5 3NR • The appeal is made under section 78 of the Town and Country Planning Act 1990 (as amended) against a refusal to grant consent, agreement or approval to details required by a condition of a planning permission. • The appeal is made by Mr James Duggan (Qiani Ltd) against the decision of Stroud District Council. • The application Ref S.24/1964/DISCON sought approval of details pursuant to condition No 11 of a planning permission Ref S.23/2551/FUL, granted on 28 February 2024. • The application was refused by notice dated 14 January 2025. • The development proposed is erection of three dwellings, demolition of shop & renovation of existing dwelling. Resubmission of S.20/1686/FUL. • The details for which approval is sought are: Surface water drainage strategy. Decision 1.

Page 1 · Chunk 1 Appeal Decision

5 Kites Nest Lane, Lightpill, STROUD, GL5 3NR — Stroud District Council — Appeal Decision The appeal is allowed and the surface water drainage strategy details submitted pursuant to condition No 11 attached to planning permission Ref S.23/2551/FUL granted on 28 February 2024, in accordance with the application reference number S.24/1964/DISCON and the plans and information submitted with it are approved. Preliminary Matters 2. Condition 11 attached to planning permission reference number S.23/2551/FUL requires the approval of a detailed design, maintenance and management strategy and timetable of implementation for surface water drainage. The appellant has submitted a surface water drainage strategy dated September 2024 (the SWDS), a regulated water and drainage report as well as a Notice of Acceptance letter from Severn Trent Water Limited dated 11 December 2024 (NoA). 3. The information before me includes details of the proposed surface water drainage system as well as information on how it would be managed and maintained. However, no timetable for the implementation of the scheme has been provided. Nonetheless, condition 11 does not stipulate that all the required information need be submitted for approval at the same time.

Page 1 · Chunk 2 Appeal Decision

5 Kites Nest Lane, Lightpill, STROUD, GL5 3NR — Stroud District Council — Appeal Decision In the interests of clarity, I confirm my assessment relates solely to the information in the documents referred to above. Main Issue 4. The main issue is whether the proposed drainage system would be acceptable and appropriate, particularly having regard to the issue of flood risk. https://www.gov.uk/planning-inspectorate

Page 1 · Chunk 3 Appeal Decision

5 Kites Nest Lane, Lightpill, STROUD, GL5 3NR — Stroud District Council — Appeal Decision In the interests of clarity, I confirm my assessment relates solely to the information in the documents referred to above. Main Issue 4. The main issue is whether the proposed drainage system would be acceptable and appropriate, particularly having regard to the issue of flood risk. https://www.gov.uk/planning-inspectorate

Page 2 · Chunk 4 Appeal Decision

5 Kites Nest Lane, Lightpill, STROUD, GL5 3NR — Stroud District Council — Appeal Decision Appeal Decision APP/C1625/W/25/3359164 Reasons 5. The appeal site contains a building that was used as a shop with living accommodation. There is an open area to the rear of the site. The parent planning permission allows the partial demolition of the existing building and the provision of 3 dwellinghouses with gardens and vehicular parking and turning areas. 6. The drainage plan included in appendix 4 of the SWDS indicates that downpipes on the houses would discharge rainwater onto new permeable paver surfacing. A drain set within a layer of open graded coarse stone under a bedding course would take surface water to a flow control device located near to the entrance of the site. Controlled outflow from the chamber would lead to an existing inspection chamber and then to the mains drainage system in the road. 7. The SWDS explains the site prior to development consists of 580m2 of impermeable surfacing and 620m2 of grass. The proposed development would include 300m2 of permeable paving as well as 350m2 of grass so it would reduce the amount of impermeable surfacing on the site to 550m2. This suggests the development would lead to a small decrease in the amount of rainwater that would flow off the site. 8.

Page 2 · Chunk 5 Appeal Decision

5 Kites Nest Lane, Lightpill, STROUD, GL5 3NR — Stroud District Council — Appeal Decision Moreover, the SWDS claims the permeable paving will provide just over 40m3 of water attenuation volume. Also, it is claimed the proposed flow control chamber would reduce the surface water discharge rate in a 1:100 year flood event to 1 litre per second. This compares to the current drainage system that the appellant claims discharges at 25 litres per second. The Council has not sought to dispute the appellant’s claims in these regards. As such, it is fair to expect the proposed system would provide a greater level of surface water attenuation compared to the existing situation. This together with the likely reduction in the amount of surface water that flows from off the site strongly suggest the development would not increase the risk of flooding elsewhere. 9. The Council’s refusal reason claims the proposed surface drainage water system would connect to a foul water mains pipe. However, the appellant has established through inspection and discussions with Severn Trent Water Limited that the mains in Kitesnest Lane is a combined foul and surface water system. In light of the NoA, I favour the appellant’s submissions in these respects.

Page 2 · Chunk 6 Appeal Decision

5 Kites Nest Lane, Lightpill, STROUD, GL5 3NR — Stroud District Council — Appeal Decision In any event, the evidence before me indicates the proposed surface water drainage system would connect to the same mains as the drainage serving the existing property. As such, the proposed drainage would not increase the amount of water disposed from the site into the mains system as claimed by the Council. 10. Policy ES4 of the Stroud District Local Plan 2015 (the LP) only allows surface water drainage to a combined sewer where discharge to the ground, to a surface water body or to a surface water sewer is not practicable. The SWDS explains that a soakaway system would be unsuitable as limestone beneath the site could lead to water flow along fissures to an unspecified point off the site. The Council has not sought to dispute this point. Also, there is no suggestion that surface water could be disposed of to a surface water body. 11. There is mention of a surface water mains sewer under the A46 Bath Road. However, to connect the proposed development to this mains would require a new connecting drain within Kitesnest Lane. Given the separation distance, I find no reason to disagree with the appellant’s claim that the costs to provide such a https://www.gov.uk/planning-inspectorate 2

Page 3 · Chunk 7 Appeal Decision

5 Kites Nest Lane, Lightpill, STROUD, GL5 3NR — Stroud District Council — Appeal Decision Appeal Decision APP/C1625/W/25/3359164 sewer would make the proposed development unviable and so it would be an impracticable solution. Therefore, the proposed connection to the combined foul and surface water mains in Kitesnest Lane would accord with the hierarchy as set out under LP policy ES4. 12. The Council raises no objections to the details on how the proposed drainage system would be managed and maintained. Therefore, for the above reasons, I conclude the proposed drainage strategy details would be acceptable and the proposed system would not increase the risk of flooding. In these regards, the proposal would accord with LP policy ES4. Other Matters 13. The boundary to a conservation area lies on the opposite side of Kitesnest Lane to the appeal site. However, the drainage system would have no effect on the setting nor the significance of the conservation area. 14. Also, the questionnaire provided by the Council indicates the appeal site is adjacent to or likely to affect a Site of Special Scientific Interest or an internationally designated site. However, no objection is raised over the specific effects of the proposed drainage system on any features of ecological or biodiversity value.

Page 3 · Chunk 8 Appeal Decision

5 Kites Nest Lane, Lightpill, STROUD, GL5 3NR — Stroud District Council — Appeal Decision Accordingly, I consider the drainage system would be acceptable in these regards. Conclusion 15. For the reasons given above, I conclude the appeal should be allowed.

Page 3 · Chunk 9 Jonathan Edwards

5 Kites Nest Lane, Lightpill, STROUD, GL5 3NR — Stroud District Council — Jonathan Edwards INSPECTOR https://www.gov.uk/planning-inspectorate 3

Extracted from the decision letter PDF and shown in full, chunk by chunk.

Main issues and findings

Flood risk
For appellant
¶8

The proposed system would provide a greater level of surface water attenuation compared to the existing situation, and would not increase the risk of flooding elsewhere.

Flood risk
For appellant
¶9

The proposed drainage would not increase the amount of water disposed from the site into the mains system.

Flood risk
For appellant
¶11

Connecting the proposed development to the surface water mains sewer under the A46 Bath Road would require a new connecting drain within Kitesnest Lane, which would be impracticable due to the costs.

Planning obligations
For appellant
¶12

The proposed drainage system would accord with LP policy ES4, and the Council raises no objections to the details on how the proposed system would be managed and maintained.

Heritage impact
For appellant
¶13

The drainage system would have no effect on the setting nor the significance of the conservation area.

Ecology and biodiversity
For appellant
¶14

No objection is raised over the specific effects of the proposed drainage system on any features of ecological or biodiversity value.

Policies relied on

Reference Weight
LP policy ES4
Determinative

Site constraints from the Casework Database

Conservation area
Green belt
Listed building setting
AONB
SSSI
Flooding an issue

Source

Decision letter, 3 pages, issued by the Planning Inspectorate on 10 April 2025 under the Open Government Licence.